Todd H. Lanman, J. Kenneth Burkus, Randall G. Dryer, Matthew F. Gornet, Jeffrey McConnell, and Scott D. Hodges

OBJECTIVE

The aim of this study was to assess long-term clinical safety and effectiveness in patients undergoing anterior cervical surgery using the Prestige LP artificial disc replacement (ADR) prosthesis to treat degenerative cervical spine disease at 2 adjacent levels compared with anterior cervical discectomy and fusion (ACDF).

开云体育世界杯赔率

A prospective, randomized, controlled, multicenter FDA-approved clinical trial was conducted at 30 US centers, comparing the low-profile titanium ceramic composite-based Prestige LP ADR (n = 209) at 2 levels with ACDF (n = 188). Clinical and radiographic evaluations were completed preoperatively, intraoperatively, and at regular postoperative intervals to 84 months. The primary end point was overall success, a composite variable that included key safety and efficacy considerations.

RESULTS

在84个月,威望LP ADR sta演示tistical superiority over fusion for overall success (observed rate 78.6% vs 62.7%; posterior probability of superiority [PPS] = 99.8%), Neck Disability Index success (87.0% vs 75.6%; PPS = 99.3%), and neurological success (91.6% vs 82.1%; PPS = 99.0%). All other study effectiveness measures were at least noninferior for ADR compared with ACDF. There was no statistically significant difference in the overall rate of implant-related or implant/surgical procedure–related adverse events up to 84 months (26.6% and 27.7%, respectively). However, the Prestige LP group had fewer serious (Grade 3 or 4) implant- or implant/surgical procedure–related adverse events (3.2% vs 7.2%, log hazard ratio [LHR] and 95% Bayesian credible interval [95% BCI] −1.19 [−2.29 to −0.15]). Patients in the Prestige LP group also underwent statistically significantly fewer second surgical procedures at the index levels (4.2%) than the fusion group (14.7%) (LHR −1.29 [95% BCI −2.12 to −0.46]). Angular range of motion at superior- and inferior-treated levels on average was maintained in the Prestige LP ADR group to 84 months.

CONCLUSIONS

The low-profile artificial cervical disc in this study, Prestige LP, implanted at 2 adjacent levels, maintains improved clinical outcomes and segmental motion 84 months after surgery and is a safe and effective alternative to fusion.

Clinical trial registration no.: NCT00637156 (clinicaltrials.gov)

Restricted access

Matthew F. Gornet, J. Kenneth Burkus, Randall F. Dryer, John H. Peloza, Francine W. Schranck, and Anne G. Copay

OBJECTIVE

Despite evidence of its safety and effectiveness, the use of lumbar disc arthroplasty has been slow to expand due in part to concerns about late complications and the risks of revision surgery associated with early devices. More recently, FDA approval of newer devices and improving reimbursements have reversed this trend in the United States. Additional long-term data on lumbar disc arthroplasty are still needed. This study reports the 5-year results of the FDA investigational device exemption clinical trial of the Medtronic Spinal and Biologics’ Maverick total disc replacement.

开云体育世界杯赔率

单层退行性椎间盘disea患者se from L4 to S1 were randomized 2:1 at 31 investigational sites. In the period from April 2003 to August 2004, 405 patients received the investigational device and 172 patients underwent the control procedure of anterior lumbar interbody fusion. Outcome measures included the Oswestry Disability Index (ODI), numeric rating scales (NRSs) for back and leg pain, the SF-36, disc height, interbody motion, heterotopic ossification (investigational device), adverse events (AEs), additional surgeries, and neurological status. Treatment was considered an overall success when all of the following criteria were met: 1) ODI score improvement ≥ 15 points over the preoperative score; 2) maintenance or improvement in neurological status compared with preoperatively; 3) disc height success, that is, no more than a 2-mm reduction in anterior or posterior height; 4) no serious AEs caused by the implant or by the implant and the surgical procedure; and 5) no additional surgery classified as a failure.

RESULTS

Compared to that in the control group, improvement in the investigational group was statistically greater according to the ODI and SF-36 Physical Component Summary (PCS) at 1, 2, and 5 years; the NRS for back pain at 1 and 2 years; and the NRS for leg pain at 1 year. The rates of heterotopic ossification increased over time: 1.0% (4/382) at 1 year, 2.6% (9/345) at 2 years, and 5.9% (11/187) at 5 years. Investigational patients had fewer device-related AEs and serious device-related AEs than the control patients at both 2 and 5 years postoperatively. Noninferiority of the composite measure overall success was demonstrated at all follow-up intervals; superiority was demonstrated at 1 and 2 years.

CONCLUSIONS

Lumbar disc arthroplasty is a safe and effective treatment for single-level lumbar degenerative disc disease, resulting in improved physical function and reduced pain up to 5 years after surgery.

Clinical trial registration no.: NCT00635843 (clinicaltrials.gov)

Free access

Matthew F. Gornet, Todd H. Lanman, J. Kenneth Burkus, Scott D. Hodges, Jeffrey R. McConnell, Randall F. Dryer, Anne G. Copay, Hui Nian, and Frank E. Harrell Jr.

OBJECTIVE

The authors compared the efficacy and safety of arthroplasty using the Prestige LP cervical disc with those of anterior cervical discectomy and fusion (ACDF) for the treatment of degenerative disc disease (DDD) at 2 adjacent levels.

开云体育世界杯赔率

Patients from 30 investigational sites were randomized to 1 of 2 groups: investigational patients (209) underwent arthroplasty using a Prestige LP artificial disc, and control patients (188) underwent ACDF with a cortical ring allograft and anterior cervical plate. Patients were evaluated preoperatively, intraoperatively, and at 1.5, 3, 6, 12, and 24 months postoperatively. Efficacy and safety outcomes were measured according to the Neck Disability Index (NDI), Numeric Rating Scales for neck and arm pain, 36-Item Short-Form Health Survey (SF-36), gait abnormality, disc height, range of motion (investigational) or fusion (control), adverse events (AEs), additional surgeries, and neurological status. Treatment was considered an overall success when all 4 of the following criteria were met: 1) NDI score improvement of ≥ 15 points over the preoperative score, 2) maintenance or improvement in neurological status compared with preoperatively, 3) no serious AE caused by the implant or by the implant and surgical procedure, and 4) no additional surgery (supplemental fixation, revision, or nonelective implant removal). Independent statisticians performed Bayesian statistical analyses.

RESULTS

The 24-month rates of overall success were 81.4% for the investigational group and 69.4% for the control group. The posterior mean for overall success in the investigational group exceeded that in the control group by 0.112 (95% highest posterior density interval = 0.023 to 0.201) with a posterior probability of 1 for noninferiority and 0.993 for superiority, demonstrating the superiority of the investigational group for overall success. Noninferiority of the investigational group was demonstrated for all individual components of overall success and individual effectiveness end points, except for the SF-36 Mental Component Summary. The investigational group was superior to the control group for NDI success. The proportion of patients experiencing any AE was 93.3% (195/209) in the investigational group and 92.0% (173/188) in the control group, which were not statistically different. The rate of patients who reported any serious AE (Grade 3 or 4) was significantly higher in the control group (90 [47.9%] of 188) than in the investigational group (72 [34.4%] of 209) with a posterior probability of superiority of 0.996. Radiographic success was achieved in 51.0% (100/196) of the investigational patients (maintenance of motion without evidence of bridging bone) and 82.1% (119/145) of the control patients (fusion). At 24 months, heterotopic ossification was identified in 27.8% (55/198) of the superior levels and 36.4% (72/198) of the inferior levels of investigational patients.

CONCLUSIONS

Arthroplasty with the Prestige LP cervical disc is as effective and safe as ACDF for the treatment of cervical DDD at 2 contiguous levels and is an alternative treatment for intractable radiculopathy or myelopathy at 2 adjacent levels.

Clinical trial registration no.: NCT00637156 (clinicaltrials.gov)