This site usescookies, tags, and tracking settings to store information that help give you the very best browsing experience. Dismiss this warning

Search Results

You are looking at1-2of2items for

  • Author or Editor: Roee Berx
  • Refine by Access: allx
Clear All Modify Search
Free access

Roee Ber, Dennis London, Samya Senan, Yasmin Youssefi, David H. Harter, John G. Golfinos, and Donato Pacione

OBJECTIVE

Miscommunication and poor coordination among surgical teams are known causes of preventable medical harms and operating room inefficiencies and inhibit surgical training. Technology may help overcome these challenges. This study used the personal experience of one of the authors as a former Air Force F-15 pilot to design a combat aviation pre- and postoperative communication workflow in the neurosurgery department and tested its effect on safety, efficiency, and education. The authors hypothesized that the adoption of this workflow through a tailored technological platform will increase compliance and improve the chances of sustainability.

开云体育世界杯赔率

Data were prospectively collected from neurosurgery cases before (January–May 2020) and after (June–October 2020) implementation of this workflow. Briefing and debriefing were executed using a custom mobile platform and were defined as nonmandatory for all participants. All faculty and residents who operated at NYU Langone Medical Center (Tisch campus) during the intervention period were enrolled on the platform. Primary outcomes were morbidity and mortality per the department’s criteria, and intraoperative last-minute requests as reported by operating room staff in a double-blinded fashion. Secondary outcomes were user responses on the subjective questionnaires.

RESULTS

Data were collected from 637 and 893 cases during the preintervention and intervention periods, respectively. The average briefing rates for residents and surgeons were 71% and 81%, respectively, and the average debriefing rates for residents and surgeons were 67% and 88%. There was no significant difference in preoperative risk score between the preintervention and intervention patient populations (p = 0.24). The rate of intraoperative last-minute requests significantly decreased from 16.6% (35/211) to 10.5% (35/334, p = 0.048). There was no significant change in morbidity and mortality between the preintervention and intervention periods. On subjective questionnaires there was a statistically significant improvement in safety, efficiency, and educational aspects of the cases during the intervention period.

CONCLUSIONS

Implementation of aviation-like structured team communication practices in the neurosurgery department through a technological platform improved education and communication between surgical teams and led to a reduction in last-minute surgical requests that could impact costs.

Restricted access

Hammad A. Khan, Roee Ber, Sean N. Neifert, David B. Kurland, Ilya Laufer, Douglas Kondziolka, Arpit Chhabra, Anthony K. Frempong-Boadu, and Darryl Lau

OBJECTIVE

通过最小化工件成像和粒子scatter, carbon fiber–reinforced polyetheretherketone (CF-PEEK) spinal implants are hypothesized to enhance radiotherapy (RT) planning/dosing and improve oncological outcomes. However, robust clinical studies comparing tumor surgery outcomes between CF-PEEK and traditional metallic implants are lacking. In this paper, the authors performed a systematic review of the literature with the aim to describe clinical outcomes in patients with spine tumors who received CF-PEEK implants, focusing on implant-related complications and oncological outcomes.

开云体育世界杯赔率

A systematic review of the literature published between database inception and May 2022 was performed in accordance with the 2020 Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. The PubMed database was queried using the terms "carbon fiber" and "spine" or "spinal." The inclusion criteria were articles that described patients with CF-PEEK pedicle screw fixation and had a minimum of 5 patients. Case reports and phantom studies were excluded.

RESULTS

This review included 11 articles with 326 patients (237 with CF-PEEK–based implants and 89 with titanium-based implants). The mean follow-up period was 13.5 months, and most tumors were metastatic (67.1%). The rates of implant-related complications in the CF-PEEK and titanium groups were 7.8% and 4.7%, respectively. The rate of pedicle screw fracture was 1.7% in the CF-PEEK group and 2.4% in the titanium group. The rates of reoperation were 5.7% (with 60.0% because of implant failure or junctional kyphosis) and 4.8% (all because of implant failure or junctional kyphosis) in the CF-PEEK and titanium groups, respectively. When reported, 72.5% of patients received postoperative RT (41.0% stereotactic body RT, 30.8% fractionated RT, 25.6% proton, 2.6% carbon ion). Four articles suggested that implant artifact was reduced in the CF-PEEK group. Local recurrence occurred in 14.4% of CF-PEEK and 10.7% of titanium-implanted patients.

CONCLUSIONS

While CF-PEEK harbors similar implant failure rates to traditional metallic implants with reduced imaging artifact, it remains unclear whether CF-PEEK implants improve oncological outcomes. This study highlights the need for prospective, direct comparative clinical studies.

Baidu
map